OEG Offshore provides living and sleeping modules to meet temporary offshore accommodation requirements around the world. These modules are manufactured to DNV 2.7-1, EN 12079 & ABS standards to ensure maximum comfort and safety for inhabitants.  

Our modules are the most modern and advanced available on the market with carefully-planned interior configurations. Accommodation modules range from 6 metre living quarters to a full-scale locker room and medic suites. Available for rental or purchase, these modules meet the requirements of offshore and renewable energy industries.

Features
  • Structural design: DNV 2.7-1, EN 12079 & ABS

  • A60 fire rated

  • 2 sets of bunks or single beds

  • Lockers including hanging and shelving space

  • En-suite wet unit

  • Shower with integral hot water system

  • Desk & workspace, including pin board and chair

  • Integral Heating, Ventilation and Air Conditioning (HVAC) system with individual room control

  • Combined pressurisation, fire and gas protection system

  • High quality fixtures and fittings

  • Attractive relaxing decor and soft furnishings

  • Quick and easy hook-up to on-board services

  • All modules designed for easy stacking

  • 10.3m modules designed for easy interlinking

  • User selectable 380V/415V/440V/460V/480V, (50Hz or 60Hz), 3 phase & Earth main power

  • Nominal load current 40A per phase @ 380V

  • Suggested vessel protection, 63A motor rated circuit breaker

  • Modules provide a variety of volt-free signal contacts which the vessel can incorporate into their own alarm system

  • Offshore Accommodation modules available for rental or sale

 

6m Offshore Accommodation Module

 6m / 20ft Offshore Accommodation Module 

Temporary Offshore Accommodation Module

10.3m / 34ft Offshore Accommodation Module

 

Technical Specification
Length (metres) Length
(ft)
Width (metres) Width
(ft)
Height (metres) Height
(ft)
MGW
(metres)
MGW
(lbs)

6 m

19' 10"

2.4

8'

2.8

9' 5"

9,500 kgs

20,944 lbs

7.6 m

25' 2"

3.5

10' 7"

3.3

10' 10"

12,000 kgs

26,455 lbs

10.3 m

33' 9"

3.3

10' 8"

3.3

10' 8"

16,000 kgs

35,274 lbs


Ancillary Modules

General-purpose modules have multi-purpose roles and configurations include medic facilities, recreational rooms, gymnasiums, locker rooms and laundry rooms.

 

Offshore Gymnasium Module

Gymnasium Module

Offshore Module Types Length (metres)

Length
(ft)

Width (metres) Width
(ft)
Height (metres) Height
(ft)
MGW
(metres)
MGW
(lbs)
Offshore Gallery 10.3 m 33.8 3.3 10.8 3.3 10.8 21,000 kgs 46,297 lbs
Offshore Recreation 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs
Offshore Laundry 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs
Offshore Gymnasium 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs
Offshore Medic Suite 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs
Offshore Locker Room 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs
Offshore Coffee / Tea Shack 10.3 m 33.8 3.3 10.8 3.3 10.8 16,000 kgs 35,274 lbs

 

Offshore Locker Room Module

Locker Room Module